<?xml version="1.0" encoding="UTF-8"?> <!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2d1 20170631//EN" "JATS-journalpublishing1.dtd"> <ArticleSet> <Article> <Journal> <PublisherName>journal-jmsr</PublisherName> <JournalTitle>Journal of Medical and Surgical Research</JournalTitle> <PISSN>I</PISSN> <EISSN>S</EISSN> <Volume-Issue>Vol. VII, n 1</Volume-Issue> <PartNumber/> <IssueTopic>Multidisciplinary</IssueTopic> <IssueLanguage>English</IssueLanguage> <Season>June, 2020</Season> <SpecialIssue>N</SpecialIssue> <SupplementaryIssue>N</SupplementaryIssue> <IssueOA>Y</IssueOA> <PubDate> <Year>-0001</Year> <Month>11</Month> <Day>30</Day> </PubDate> <ArticleType>JMSR Anesthesiology and IC</ArticleType> <ArticleTitle>Non-Invasive Versus Invasive Blood Pressure Monitoring in Patients During Laparoscopic Bariatric Surgery: a Prospective Method-Comparison Study</ArticleTitle> <SubTitle/> <ArticleLanguage>English</ArticleLanguage> <ArticleOA>Y</ArticleOA> <FirstPage>778</FirstPage> <LastPage>791</LastPage> <AuthorList> <Author> <FirstName>Chua Shiau</FirstName> <LastName>Ying</LastName> <AuthorLanguage>English</AuthorLanguage> <Affiliation/> <CorrespondingAuthor>N</CorrespondingAuthor> <ORCID/> <FirstName>Loo Guo</FirstName> <LastName>Hou</LastName> <AuthorLanguage>English</AuthorLanguage> <Affiliation/> <CorrespondingAuthor>Y</CorrespondingAuthor> <ORCID/> <FirstName>Azarinah</FirstName> <LastName>Izaham</LastName> <AuthorLanguage>English</AuthorLanguage> <Affiliation/> <CorrespondingAuthor>Y</CorrespondingAuthor> <ORCID/> <FirstName>Reynu</FirstName> <LastName>Rajan</LastName> <AuthorLanguage>English</AuthorLanguage> <Affiliation/> <CorrespondingAuthor>Y</CorrespondingAuthor> <ORCID/> <FirstName>Zuraidah</FirstName> <LastName>Che’Man</LastName> <AuthorLanguage>English</AuthorLanguage> <Affiliation/> <CorrespondingAuthor>Y</CorrespondingAuthor> <ORCID/> <FirstName>Esa</FirstName> <LastName>Kamaruzaman</LastName> <AuthorLanguage>English</AuthorLanguage> <Affiliation/> <CorrespondingAuthor>Y</CorrespondingAuthor> <ORCID/> <FirstName>Nik Ritza</FirstName> <LastName>Kosai</LastName> <AuthorLanguage>English</AuthorLanguage> <Affiliation/> <CorrespondingAuthor>Y</CorrespondingAuthor> <ORCID/> </Author> </AuthorList> <DOI>10.46327/msrjg.1.000000000000171</DOI> <Abstract>Introduction: Intra-operative blood pressure monitoring in morbidly obese patients using standard non-invasive blood pressure (NIBP) oscillometric technique with upper arm cuffing is often inaccurate. Invasive arterial blood pressure (IABP) monitoring is the gold standard but is not without complications. The purpose of this study was done to assess the degree of agreement between the forearm and upper arm NIBP with the IABP during laparoscopic bariatric surgery. Patients and Methodsm The study was conducted in our university hospital. A total of 36 morbidly obese patients undergoing laparoscopic bariatric surgery were studied. The radial artery was cannulated for IABP monitoring on one upper limb while NIBP monitoring was done on the contralateral upper arm and forearm. The NIBP and its corresponding IABP readings were recorded at selected time points at 10 minutes post-induction; 5, 15, and 30 minutes post-insufflation and 15 minutes post- exsufflation. Results: The mean arterial pressure (MAP) has narrower limits of agreement compared to the systolic blood pressure (SBP) and diastolic blood pressure (DBP) for each method of measurement used. Forearm NIBP showed better agreement with IABP compared to upper arm NIBP. Repeated measures ANOVA showed a similar pattern of changes in SBP, DBP, and MAP measured by NIBP and IABP during the surgery. Conclusion: Similar patterns of blood pressure changes were observed with IABP, upper arm, and forearm NIBP measurements at all time points. The forearm NIBP showed better agreement to IABP as compared to upper arm NIBP and may be adequate to monitor patterns of blood pressure changes during laparoscopic bariatric surgery.</Abstract> <AbstractLanguage>English</AbstractLanguage> <Keywords>Weight loss surgery,intraoperative BP monitoring,Obesity,Hypertension,Forearm and upper arm BP monitoring,IABP,NIBP</Keywords> <URLs> <Abstract>https://journal-jmsr.net/ubijournal-v1copy/journals/abstract.php?article_id=7705&title=Non-Invasive Versus Invasive Blood Pressure Monitoring in Patients During Laparoscopic Bariatric Surgery: a Prospective Method-Comparison Study</Abstract> </URLs> <References> <ReferencesarticleTitle>References</ReferencesarticleTitle> <ReferencesfirstPage>16</ReferencesfirstPage> <ReferenceslastPage>19</ReferenceslastPage> <References>1. Hayden P, Cowman S. Anaesthesia for laparoscopic surgery. Contin Educ Anaesth Crit Care Pain. 2011;11(5):177-80. 2. Nguyen NT, Wolfe BM. The physiologic effects of pneumoperitoneum in the morbidly obese. Ann Surg. 2005;241(2):219-26. 3. Poirier P et al. Obesity and cardiovascular disease: pathophysiology, evaluation, and effect of weight loss: an update of the 1997 American Heart Association Scientific Statement on Obesity and Heart Disease from the Obesity Committee of the Council on Nutrition, Physical Activity, and Metabolism. Circulation. 2006;113(6):898-918. 4. Bartels K, Esper SA, Thiele RH. Blood pressure monitoring for the anesthesiologist: a practical review. Anesth Analg. 2016;122(6):1866-79. 5. Anast N, Olejniczak M, Ingrande J, Brock-Utne J. The impact of blood pressure cuff location on the accuracy of noninvasive blood pressure measurements in obese patients: an observational study. Can J Anesth/J Can Anesth. 2015;63(3):1-9. 6. Hersh et al. Validation of a conical cuff on the forearm for estimating radial artery blood pressure. Blood Press Monit. 2014;19(1):38-45. 7. Irving G et al. Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review.BMJ Open. 2016 Nov 3;6(11):e012429. doi: 10.1136/bmjopen- 2016-012429. 8. Palatini P, Parati G. Blood pressure measurement in very obese patients: a challenging problem. J Hypertens. 2011;29(3):425-9. 9. Clark CE, Taylor RS, Shore AC, Ukoumunne OC, Campbell JL. Association of a difference in systolic blood pressure between arms with vascular disease and mortality: a systematic review and meta-analysis. Lancet. 2012;379(9819):905-14. 10. Hager H et al. A comparison of noninvasive blood pressure measurement on the wrist with invasive arterial blood pressure monitoring in patients undergoing bariatric surgery. Obes Surg. 2009;19(6):717-24. 11. Pierin AM, Alavarce DC, Gusmao JL, Halpern A, Mion D. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements. Blood Press Monit. 2004;9(3):101-5. 12. Schell K et al. Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm. Am J Crit Care. 2005;14(3):232-41. 13. Singer AJ, Kahn SR, Thode HC Jr, Hollander JE. Comparison of forearm and upper arm blood pressures. Prehosp Emerg Care. 1999;3(2):123-6. 14. Schell K, Morse K, Waterhouse JK. Forearm and upper-arm oscillometric blood pressure comparison in acutely ill adults. West J Nurs Res. 2010;32(3):322-40. 15. Leblanc ME, Croteau S, Ferland A, Bussieres J, Cloutier L, Hould FS, et al. Blood pressure assessment in severe obesity: validation of a forearm approach. Obesity. 2013;21(12):E533-41. 16. Mignini MA, Piacentini E, Dubin A. Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study. Crit Care. 2006;10(2):R43. 17. Dumont L, Mattys M, Mardirosoff C, Picard V, Alle JL, Massaut J. Hemodynamic changes during laparoscopic gastroplasty in morbidly obese patients. Obes Surg. 1997;7(4):326-31. 18. Balderi T, Forfori F, Marra V, Di Salvo C, Dorigo M, Anselmino M, et al. Continuous hemodynamic monitoring during laparoscopic gastric bypass in superobese patients by pressure recording analytical method. Obes Surg. 2008;18(8):1007-14.</References> </References> </Journal> </Article> </ArticleSet>